Beam test of a prototype CsI calorimeter

Beam test of a prototype CsI calorimeter
复制标题

CsI 量热仪原型的光束测试

DOI:
10.1016/0168-9002(95)00677-x
复制
发表时间:
1996
影响因子:
1.4
通讯作者:
M. Lindgren
M. Lindgren
中科院分区:
物理与天体物理3区
文献类型:
--
作者:
R. Kessler;A. Roodman;P. Shawhan;N. Solomey;B. Winstein;S. Hansen;H. Nguyen;R. Ray;R. Tschirhart;J. Whitmore;T. Nakaya;M. Lindgren

文献摘要

被引文献

相似文献

用于费米实验室KTeV实验的原型电磁量热计在CERN X1束线上进行了测试。量热计由未掺杂的碘化铯晶体组成,这些晶体暴露在电子、介子和µ子中。这项测试还采用了一种新的数字读出系统,具有17位动态范围。电子能量分辨率在5GeV/c时优于1%,在60GeV/c时小于0.5%,对40GeV/c电子的拒绝因子估计为几百倍,电子效率为95%。
A prototype electromagnetic calorimeter for the KTeV experiment at Fermilab was tested at the CERN X1 beam-line. The calorimeter consisted of undoped cesium iodide crystals which were exposed to electrons, pions and muons. This test also featured a new digital readout system with 17 bits of dynamic range. The electron energy resolution is better than 1% at 5 GeV/c, and less than 0.5% at 60 GeV/c. The rejection factor for 40 GeV/c pions is estimated to be several hundred with 95% electron efficiency.