Dynamic stiffness and transmissibility of commercially available wheelchair cushions using a laboratory test method
Dynamic stiffness and transmissibility of commercially available wheelchair cushions using a laboratory test method
复制标题
DOI:
10.1682/jrrd.2011.02.0023
复制
发表时间:
2012-01-01
影响因子:
--
通讯作者:
Boninger, Michael L.
中科院分区:
文献类型:
--
作者:
Garcia-Mendez, Yasmin;Pearlman, Jonathan L.;Boninger, Michael L.
Evidence suggests that wheelchair (WC) users are exposed to unhealthy levels of vibration during WC use. Health risks associated with vibration exposure include vertebral disc degeneration and back pain, which may consequently decrease the function and independence of WC users. Some evidence suggests that the cushions used in WCs may amplify vibrations, although conclusive evidence has not been presented in the literature. This study evaluated and compared the transmissibility of commercially available WC cushions with two laboratory test methods: (1) direct measurement of transmissibility while human subjects propelled a WC over a road course with different cushions and (2) characterization of cushions with a material testing system (MTS) combined with mathematical models of the apparent mass of the human body. Results showed that although dynamic characterization of WC cushions is possible with an MTS, the results did not correlate well with the transmissibility obtained in the WC road course. Significant differences were found for transmissibility among the cushions tested, with the air-based cushions having lower transmissibility than the foam- or gel-based cushions.