Experimental and numerical investigation on suppression of thermal stratification in a water-pool: PIV measurements and CFD simulations
Experimental and numerical investigation on suppression of thermal stratification in a water-pool: PIV measurements and CFD simulations
复制标题
DOI:
10.1016/j.applthermaleng.2018.04.070
复制
发表时间:
2018-06
影响因子:
6.4
通讯作者:
Sunil Kumar;R. Grover;H. Yadav;P. Vijayan;Umasankari Kannan;A. Agrawal
中科院分区:
文献类型:
--
作者:
Sunil Kumar;R. Grover;H. Yadav;P. Vijayan;Umasankari Kannan;A. Agrawal
This paper deals with experimental and numerical investigation on thermal stratification phenomenon conducted in a scaled transparent pool using Particle Image Velocimetry (PIV) technique and Computational Fluid Dynamics (CFD) simulations respectively. Experiments were designed to simulate thermal stratification in a pool with an immersed heat exchanger. In general, pools with an immersed heat exchanger tend to get thermally stratified; preventing mixing and participation of the whole pool during the heat removal process. The study presented in the paper, focuses on quantification of thermal stratification in the pool without shrouds and examines the effect of shrouds on suppression of thermal stratification. The installation of three shrouds divides the pool in four compartments and ensures participation of the whole pool inventory in the heat removal process. In all the four compartments, pool water circulation was observed since the beginning of the heat transfer from the heater. In a three-shroud configuration, because of mixing, rate of rise of temperature of water near the top decreases.