Research on Rotor Air Friction Loss of High-speed Permanent Magnet Machines
Research on Rotor Air Friction Loss of High-speed Permanent Magnet Machines
复制标题
DOI:
--
复制
发表时间:
2010
期刊:
影响因子:
--
通讯作者:
Kong Xiaoguang
中科院分区:
文献类型:
--
作者:
Kong Xiaoguang
For a high-speed machine,the rotor speed can reach up to or even above 10 000 r/min,and the air friction loss of its rotor surface is much greater than that of a traditional one,which accounts for a large proportion in the total losses.Since the air friction loss is affected by many factors,such as rotor speed,structure of air-gap,roughness of rotor surface,etc,it is difficult to accurately calculate the air friction loss by theoretical analysis.In this paper,the relationship between rotor friction loss and rotor speed,the roughness of rotor surface,and the axial velocity of airflow were investigated based on 3D fluid field analysis.Taking an example of a high-speed permanent magnet(PM) machine whose rotor is magnetically suspended with rated speed of 60 000 r/min,the calculation and experimental determination methods for air friction loss were studied.Through the no load experiments for different speeds,the friction loss can be separated from the total losses of the machine based on the relationship between the air friction loss and rotor speed determined by the 3D finite element analysis of fluid field.The calculated friction losses accorded with the tested results,which proved the validity of the proposed calculation method for friction loss.