Widebeam ultrasonic flowmeter
Widebeam ultrasonic flowmeter
复制标题
宽束超声波流量计
DOI:
10.1109/ultsym.1990.171380
复制
发表时间:
1990
期刊:
影响因子:
--
通讯作者:
T. Sato
中科院分区:
文献类型:
--
作者:
R. Motegi;S. Takeuchi;T. Sato
A novel method of a clamp-on ultrasonic flowmeter is proposed. With this method, a widebeam is examined theoretically by the application of spatial frequency analysis. It is demonstrated that plate modes generated in a pipe wall exert bad effects on flowrate measurement. This method can reduce such effects. This method makes it possible to automatically compensate for the deviation of the transit path caused by the temperature change, and to measure the flowrate even if the sound velocity is unknown.<<ETX>>