Wideband Measurement System of ΔHω using All Shielded Shorted Microstrip Line
Wideband Measurement System of ΔHω using All Shielded Shorted Microstrip Line
复制标题
采用全屏蔽短接微带线的宽带ΔHω测量系统
DOI:
10.3379/msjmag.0903rf8034
复制
发表时间:
2009
影响因子:
--
通讯作者:
H. Suzuki
中科院分区:
文献类型:
--
作者:
S. Takeda;H. Suzuki
The wideband measurement system of ΔHω, FMR (ferromagnetic resonance) line width of microwave ferrite, is proposed. In this system, an all shielded shorted microstrip line is used as a test fixture and a specimen is inserted close to the short end. The absorption curve of FMR is observed by monitoring S11 of fixture and sweeping frequency in VNA (vector network analyzer) under constant external magnetic field. From these data, the frequency width Δω, at which an imaginary part μ” of complex permeability becomes half of maximum at resonance, is derived based on lumped element circuit model and ΔH is calculated by ΔH[Oe]=Δω[MHz]/2.8. As this ΔH is different from conventional ΔH, this is designated ΔHω. The wideband measurement result of ΔHω for 5mm square garnet slab over from 0.7[GHz] to 11[GHz] using just one test fixture is reported.