The effect of niobium ion implantation on the oxidation behavior of aγ-TiAl-based intermetallic
The effect of niobium ion implantation on the oxidation behavior of aγ-TiAl-based intermetallic
复制标题
DOI:
10.1007/bf01046882
复制
发表时间:
1996-08
影响因子:
2.2
通讯作者:
M. F. Stroosnijder;N. Zheng;W. Quadakkers;R. Hofman;A. Gil;F. Lanza
中科院分区:
文献类型:
--
作者:
M. F. Stroosnijder;N. Zheng;W. Quadakkers;R. Hofman;A. Gil;F. Lanza
The effect of niobium implantation (2×1016and 1017ions/cm2) on the oxidation behavior of a γ-TiAl-based intermetallic alloy Ti−48Al−2Cr in air at 800°C has been examined. Isothermal studies with exposure times up to 200 hr and cyclic-oxidation tests up to 800 hr revealed a negligible effect for the low implantation dose. However, a remarkable decrease in oxidation rates was observed for the material implanted with 1017Nb ions/cm2. The improvement in the oxidation resistance appeared to be similar to that obtained by alloying of the intermetallic with a few atomic percent niobium. Possible mechanisms for the effect of niobium on the oxidation resistance of TiAl-base intermetallics are discussed in view of the results obtained for the implanted material.