Design and Evaluation of an Air-Stripping Tower for Removing VOCs From Groundwater
Design and Evaluation of an Air-Stripping Tower for Removing VOCs From Groundwater
复制标题
去除地下水中 VOC 的气提塔的设计与评估
DOI:
10.1002/j.1551-8833.1986.tb05815.x
复制
发表时间:
1986
影响因子:
--
通讯作者:
B. Lykins
中科院分区:
文献类型:
--
作者:
D. Hand;J. Crittenden;J. Gehin;B. Lykins
An air-stripping tower was designed to treat 1500 gpm (0.09464 m3/s) of groundwater contaminated with trichloroethene, tetrachloroethene, cis1,2-dichloroethene, toluene, ethyl benzene, and isomers of xylene. A simplified procedure for designing a tower with the smallest volume and energy requirements was used. Data for the first four months of operation demonstrated excellent removals for the six volatile organic compounds. The cost of treatment was about $0.0586/1000 gal (3.785 m3) of water treated. Operating problems, microbiological analyses, and data regarding total organic halogen (TOX) and TOX formation potential are summarized.