Impurity behaviour in LHD long pulse discharges
Impurity behaviour in LHD long pulse discharges
复制标题
LHD 长脉冲放电中的杂质行为
DOI:
10.1088/0741-3335/44/10/304
复制
发表时间:
2002
期刊:
影响因子:
--
通讯作者:
O. Motojima
中科院分区:
文献类型:
--
作者:
Y. Nakamura;Y. Takeiri;B. Peterson;S. Muto;K. Ida;H. Funaba;M. Yokoyama;K. Narihara;Y. Nagayama;S. Inagaki;T. Tokuzawa;S. Morita;M. Goto;K. Sato;M. Osakabe;S. Masuzaki;H. Suzuki;R. Kumazawa;T. Mutoh;T. Shimozuma;M. Sato;N. Noda;K. Kawahata;N. Ohyabu;O. Motojima
Intrinsic impurity behaviour in neutral beam heated LHD long pulse discharges with a discharge duration of 10 s was investigated. Spectroscopic and bolometric measurements showed a remarkable temporal increase of core radiation due to metallic impurities. Central impurity accumulation was found in a narrow plasma density region (e = 1–3×1019 m−3) for both density ramp-up discharges and constant density discharges. In the density ramp-up discharges, high-Z impurities were accumulated in the low-density region and diffused out from the core plasma in the high-density region. The impurity behaviour was compared with neoclassical predictions.