Evaluation of the characteristics of various types of coils for the embolization of intracranial aneurysms with an optical pressure sensor system
Evaluation of the characteristics of various types of coils for the embolization of intracranial aneurysms with an optical pressure sensor system
复制标题
光学压力传感器系统评价颅内动脉瘤栓塞用各类弹簧圈的特性
DOI:
10.1007/s00234-010-0722-5
复制
发表时间:
2011
期刊:
影响因子:
--
通讯作者:
Hideo Fujimoto
中科院分区:
文献类型:
--
作者:
Noriaki Matsubara;Shigeru Miachi;Yoshitaka Nagano;Tomotaka Ohshima;Osamu Hososhima;Takashi Izumi;Arihito Tsurumi;Toshihiko Wakabayashi;Akihito Sano;Hideo Fujimoto
IntroductionIn coil embolization for an intracranial aneurysm, it is important to appropriately choose the coil most suitable for coping with various unforeseen situations. Additionally, because dense coil packing of the aneurysm sac is the most important factor to avoid a recurrence, properly selecting the coil is essential. In this article, the authors measured the coil insertion pressure of various types of coils with a newly developed sensor system, and coil characteristics were investigated.MethodsThe sensor consists of a hemostatic valve connected to the proximal end of a microcatheter. The sensor principle is based on an optical system. Using this, an experimental silicone aneurysm embolization was performed automatically at constant speed. The pattern of the insertion pressure and the maximum insertion pressure (MIP) were analyzed for the various types of coils. The sensor continuously monitored the mechanical force during the insertions.ResultsThe sensor adequately recorded the coil insertion pressure during embolization in each coil. MIP was generally ranked in order of the coil type. The soft type coils required relatively less insertion pressure than standard/helical and 3D type. As for the patterns of coil insertion pressure, each coil presented a saw-like pressure pattern, though we observed some slight differences. 3D type coils showed peak pressure at the moment of “painting”. Coil loop diameters barely affected MIP. However, as to the patterns of pressure, larger size coils more often presented the peak.ConclusionsCoil characteristics were well evaluated. The results obtained here reflected some actual clinical experience. Furthermore, collecting the in vivo study is mandatory, which may provide clinically useful data.
登录
查看更多内容
DOI:
--
发表时间:
2008
期刊:
影响因子:
--
作者:
Y. Nagano;A. Sano;M. Sakaguchi;H. Fujimoto
通讯作者:
H. Fujimoto
DOI:
10.1016/s0150-9861(04)97026-5
发表时间:
2004
期刊:
Journal of neuroradiology. Journal de neuroradiologie
影响因子:
--
作者:
R. Sellar;P. White;L. Horribine;P. Keston
通讯作者:
P. Keston
DOI:
--
发表时间:
2007
期刊:
影响因子:
--
作者:
Y. Nagano;A. Sano;M. Sakaguchi;Hideo Fujimoto
通讯作者:
Hideo Fujimoto
影响因子:
4.8
作者:
E. Veznedaroglu;C. Koebbe;A. Siddiqui;R. Rosenwasser
通讯作者:
R. Rosenwasser
DOI:
10.5797/jnet.1.45
发表时间:
2007
期刊:
Journal of Neuroendovascular Therapy
影响因子:
--
作者:
K. Sugiu;K. Tokunaga;A. Nishida;H. Hayase;S. Ono;K. Onoda;I. Date
通讯作者:
I. Date