The biocompatibility (cell culture and histologic study) of hydroxy-apatite-coated implants created by ion beam dynamic mixing.
The biocompatibility (cell culture and histologic study) of hydroxy-apatite-coated implants created by ion beam dynamic mixing.
复制标题
通过离子束动态混合创建的羟基磷灰石涂层植入物的生物相容性(细胞培养和组织学研究)。
DOI:
10.1034/j.1600-0501.1996.070202.x
复制
发表时间:
1996
影响因子:
4.3
通讯作者:
T. Dérand
中科院分区:
文献类型:
--
作者:
M. Yoshinari;B. Klinge;T. Dérand
Titanium implants were coated with hydroxyapatite by using a method of ion beam dynamic mixing. Coated and noncoated plates of titanium were placed in a growth medium with fibroblast cells. Implant screws, coated and noncoated, were inserted in rabbit bones and the animals were euthanized after 7, 27, and 122 days, respectively. The results from the cell culture test showed no visible difference between the specimens. Histologic examination of implant specimens indicated more new bone activity against coated screws at 27 days, and that was more pronounced at 127 days. Although the amount of new bone formation was not significantly different, certain signs of favourable new bone formation could be seen in contact with coated implants compared to the noncoated controls.