THE SENSITIVITY OF EXPERIMENTS WHICH USE GRADIENT PULSES FOR COHERENCE-PATHWAY SELECTION
THE SENSITIVITY OF EXPERIMENTS WHICH USE GRADIENT PULSES FOR COHERENCE-PATHWAY SELECTION
复制标题
DOI:
10.1006/jmra.1994.1227
复制
发表时间:
1994-11-01
期刊:
影响因子:
--
通讯作者:
KEELER, J
中科院分区:
文献类型:
--
作者:
KONTAXIS, G;STONEHOUSE, J;KEELER, J
The use of field-gradient pulses for coherence selection in multidimensional NMR experiments may cause a reduction in sensitivity per unit time when compared to experiments which use phase cycling. In addition, care must be taken to introduce the gradients in such a way as to retain the possibility of producing spectra with pure phase (i.e., absorption-mode lineshapes). The commonly used methods of implementing gradient pulses in multidimensional experiments are evaluated and compared with respect to these issues. These predictions are confirmed for a simple molecular system. The experimentally achieved sensitivities are also compared, on a residue-by-residue basis, for the case of different nitrogen-15 proton HSQC spectra of a 166 residue protein. (C) 1994 Academic Press, Inc.