Comparison of Donor Cornea Endothelial Cell Density Determined by Eye Banks and by a Central Reading Center in the Cornea Preservation Time Study.
Comparison of Donor Cornea Endothelial Cell Density Determined by Eye Banks and by a Central Reading Center in the Cornea Preservation Time Study.
复制标题
角膜保存时间研究中眼库和中央阅读中心测定的供体角膜内皮细胞密度的比较。
DOI:
10.1097/ico.0000000000001846
复制
发表时间:
2019
期刊:
影响因子:
2.8
通讯作者:
Lass,J
中科院分区:
文献类型:
--
作者:
Benetz,BethAnn;Stoeger,ChristopherG;Patel,SanjayV;OʼBrien,RobertC;Szczotka-Flynn,LorettaB;Ayala,AllisonR;Maguire,MaureenG;Menegay,HarryJ;Bedard,Peter;Clover,JamesonM;Gupta,PankajC;McCoy,KristenE;Song,JonathanC;Lass,J
Purpose:To evaluate agreement between eye banks (EBs) and a reading center on endothelial cell density (ECD) determinations in the Cornea Preservation Time Study.Methods:The Cornea Image Analysis Reading Center (CIARC) performed variable frame image analysis on EB-obtained–preoperative central endothelial images (after lamellar dissection for Descemet stripping automated endothelial keratoplasty by the EBs or before shipping, if surgeon prepared) to determine ECD. The EBs performed their usual method of ECD determination. The CIARC and EBs also provided ECD determinations from screening central endothelial images taken by the EBs during donor evaluation. Two independent masked CIARC readers determined ECD with measurements averaged.Results: