Low-cycle dwell-time fatigue in Ti-6242

Low-cycle dwell-time fatigue in Ti-6242
复制标题

DOI:
10.1007/s11661-999-0246-y
复制
发表时间:
1999-07
期刊:
Metallurgical and Materials Transactions A
影响因子:
--
通讯作者:
M. E. Kassner;Y. Kosaka;J. S. Hall
M. E. Kassner;Y. Kosaka;J. S. Hall
中科院分区:
其他
文献类型:
--
作者:
M. E. Kassner;Y. Kosaka;J. S. Hall

文献摘要

被引文献

相似文献

对Ti-6Al-2Sn-4 Zr-2 Mo-0.1Si(Ti-6242)进行了室温、低周停留时间和常规低周疲劳试验。试样在低于β转变的各种温度下进行固溶退火,以控制初级α相的体积分数,随后进行喷丸处理。测定了初生α相的变化对低周停留时间疲劳寿命(LCDF)的影响,并与合金的常规低周疲劳(LCF)性能进行了比较。120秒的停留时间显著减少了失效循环次数,尽管从停留时间开始LCF的系数降低,一般来说,随着应力的降低而减少。与较低固溶温度相关的初生α相的增加似乎增加了对低循环停留时间疲劳的敏感性。它也出现了驻留疲劳的敏感性可能与环境温度,时间依赖性,循环(蠕变)塑性。
Ambient-temperature, low-cycle dwell-time and conventional low-cycle fatigue tests were performed on Ti-6Al-2Sn-4Zr-2Mo-0.1Si (Ti-6242). Specimens were solution annealed at various temperatures below the beta transus to control the volume fraction of primary alpha phase and were subsequently shot-peened. The influence of the changes in primary alpha phase on the low-cycle dwell-time fatigue life (LCDF) were determined and compared to the conventional low-cycle fatigue (LCF) properties of the alloy. A 120-second dwell significantly decreased the number of cycles to failure, although the factor decrease of LCF from a dwell, in general, diminished with decreasing stress. The Increasing primary alpha phase associated with lower solution temperatures appears to increase susceptibility to low-cycle dwell-time fatigue. It also appears that the susceptibility to dwell fatigue may be associated with ambient-temperature, time-dependent, cyclic (creep) plasticity.