MColiPAT kit for early detection of coliforms in water
MColiPAT kit for early detection of coliforms in water
复制标题
MColiPAT 试剂盒用于早期检测水中的大肠菌群
DOI:
--
复制
发表时间:
2020
期刊:
影响因子:
--
通讯作者:
AkhilendraBhushan Gupta
中科院分区:
文献类型:
--
作者:
Ashish Tambi;U. Brighu;AkhilendraBhushan Gupta
Determining the microbial quality of drinking water by assessing the presence/absence (P/A) or enumeration of indicator bacteria continues to be widely practiced worldwide. However, rapid tests are required for microbiological water quality assessment so that the information is available in the shortest possible time for initiating a timely intervention. Traditional methods for the enumeration of indicator bacteria are not only expensive but also need trained personnel. We have developed a low-cost kit, ColiPAT, and have validated its application for detection of coliforms in drinking water using the IDEXX Colilert-18 Quanti tray method. ColiPAT kit medium was able to detect coliforms down to a level of 3.1 MPN/100 ml within 10.5 hours. The sensitivity and specificity of the kit were 95.45% and 100% respectively. ColiPAT is found to be reliable and accurate for the detection of coliforms in drinking water. doi: 10.2166/ws.2020.008 ://iwaponline.com/ws/article-pdf/20/3/871/765351/ws020030871.pdf Ashish Tambi (corresponding author) Urmila Brighu A. B. Gupta Department of Civil Engineering, Malaviya National Institute of Technology, Jaipur, 302017 Rajasthan, India E-mail: ashishtambi006@gmail.com