Slug length monitoring in liquid-liquid Taylor-flow integrated in a novel PVDF micro-channel
Slug length monitoring in liquid-liquid Taylor-flow integrated in a novel PVDF micro-channel
复制标题
DOI:
10.1016/j.cej.2012.08.070
复制
发表时间:
2013-07-01
影响因子:
15.1
通讯作者:
Schomburg, W. K.
中科院分区:
文献类型:
--
作者:
Burlage, K.;Gerhardy, C.;Schomburg, W. K.
A polyvinylidene fluoride (PVDF) micro-sensor channel with integrated gold wires was developed and manufactured by ultrasonic hot embossing and welding. The sensor channel was employed to detect the slug length distribution in a liquid-liquid Taylor-flow by conductivity measurements. The sensor channel was also tested regarding its usability for the detection of blockages by hot wire anemometry. (C) 2012 Elsevier B.V. All rights reserved.