Compact automated apparatus for rapid astatine recovery from nitric acid media: Design, application, and impurity characterization
Compact automated apparatus for rapid astatine recovery from nitric acid media: Design, application, and impurity characterization
复制标题
用于从硝酸介质中快速回收砹的紧凑型自动化装置:设计、应用和杂质表征
DOI:
10.1016/j.cej.2022.136176
复制
发表时间:
2022
影响因子:
15.1
通讯作者:
Harvey, Bryan
中科院分区:
文献类型:
--
作者:
Tereshatov, Evgeny E.;Burns, Jonathan D.;Schultz, Steven J.;McCann, Laura A.;McIntosh, Lauren A.;Tabacaru, Gabriel C.;Berko, Matthew;Engelthaler, Emily;Hannaman, Andrew;Harvey, Bryan
Automation of irradiated bismuth target dissolution and astatine recovery from nitric acid media has been achieved at Texas A&M University. This process can be controlled remotely; it does not require any chemical treatment or evaporation of dissolution solution prior to the separation of above-mentioned elements on an extraction chromatography column, making the final product ready within 20 min. The accompanying radio-impurities have been identified and successfully separated from astatine, leading to greater than 99% radiopurity of the desired fractions. The system consists of only one pump and a set of LabVIEW controlled valves, and allows the connection of up to 10 different columns, providing the opportunity to prepare a variety of air dry columns, which can be different column geometries, containing astatine ready for further chemistry or shipment to desired facilities.