Thermographic power accounting in MAST
Thermographic power accounting in MAST
复制标题
MAST 中的热成像功率核算
DOI:
10.1016/j.jnucmat.2004.10.053
复制
发表时间:
2005
影响因子:
3.1
通讯作者:
A. Herrmann
中科院分区:
文献类型:
--
作者:
F. Lott;A. Kirk;G. Counsell;J. Dowling;D. Taylor;T. Eich;A. Herrmann
Target heat loads calculated from the infrared camera on MAST are presented. A parameter (α) is used to account for surface effects. In L-Mode discharges, the energy arriving at the targets, as calculated from the camera using a suitable choice of α, is in agreement with that calculated from Langmuir probes and that lost from the core. In H-Mode, energy balance can also be achieved both at the ELM and in inter-ELM periods, although a different value of α is required for different targets and for different power loads. This may be due to increased erosion leading to the production of dust in the plasma sheath.