High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography - Experience on a 32-channel system
High-resolution whole-body magnetic resonance image tumor staging with the use of parallel imaging versus dual-modality positron emission tomography-computed tomography - Experience on a 32-channel system
复制标题
DOI:
10.1097/01.rli.0000185878.61270.b0
复制
发表时间:
2005-12-01
影响因子:
6.7
通讯作者:
Schoenberg, SO
中科院分区:
文献类型:
--
作者:
Schmidt, GP;Baur-Melnyk, A;Schoenberg, SO
Objective: The objective of this study was to compare the accuracy in staging of various malignant tumors with whole-body magnetic resonance imaging (WB-MRI) using parallel imaging (PAT) and positron emission tomography-computed tomography (PET-CT).Materials and Methods: In a prospective study, 41 patients with oncologic diseases underwent [F-18]-fluoro-2-deoxy-D-glucose PET-CT for tumor staging and WB-MRI on a 32-channel-scanner with the use of PAT. Coronal T1w and STIR sequences at 5 body levels, axial HASTE imaging of the lung, and contrast-enhanced T1w sequences of the liver, brain, and abdomen were performed. TNM stage was assessed for both modalities in a separate consensus reading using histologic results and radiologic follow up within 6 months as the standard of reference.Results: Three primary and 4 recurrent tumors were detected; one recurrent tumor was missed with WB-MRI. Sixty benign and 60 malignant lymph nodes were detected with a sensitivity of 98% and specificity of 83% for PET-CT and 80%/75% for WB-MRI, respectively. One hundred ninety-one malignant and 77 benign distant lesions were detected with a sensitivity/specificity of 82% for PET-CT and 96'Yo/82% for WB-MRI. Accuracy for correct TNM staging was 96% for PET-CT and 91% for WB-MRI.Conclusion: W13-MRI and PET-CT are reliable imaging modalities for tumor staging. WB-MRI is highly sensitive in detecting distant inetastases; PET-CT is superior in lymph node staging. PAT makes high-resolution W13-MRI feasible within less than 1 hour.