Quality assurance assessment of diagnostic and radiation therapy-simulation CT image registration for head and neck radiation therapy: anatomic region of interest-based comparison of rigid and deformable algorithms.
Quality assurance assessment of diagnostic and radiation therapy-simulation CT image registration for head and neck radiation therapy: anatomic region of interest-based comparison of rigid and deformable algorithms.
复制标题
DOI:
10.1148/radiol.14132871
复制
发表时间:
2015-03
期刊:
影响因子:
19.7
通讯作者:
Fuller CD
中科院分区:
文献类型:
--
作者:
Mohamed AS;Ruangskul MN;Awan MJ;Baron CA;Kalpathy-Cramer J;Castillo R;Castillo E;Guerrero TM;Kocak-Uzel E;Yang J;Court LE;Kantor ME;Gunn GB;Colen RR;Frank SJ;Garden AS;Rosenthal DI;Fuller CD
To develop a quality assurance (QA) workflow using a robust, curated, manually-segmented anatomic ROI library as a benchmark for quantitative assessment of different image registration techniques used for head and neck radiation therapy-simulation CT (SimCT) to diagnostic CT (DxCT) co-registration. SimCTs and DxCTs of twenty patients with head and neck squamous cell carcinoma treated with curative-intent intensity modulated radiotherapy (IMRT) between August 2011 and May 2012 were retrospectively retrieved under an institutional review board approval. 68 reference anatomic regions of interest (ROIs) in addition to gross tumor and nodal targets were then manually contoured on each scan. DxCT was registered to SimCT rigidly, and through 4 different deformable image registration (DIR) algorithms; Atlas-based, B-spline, demons, and optical flow. The resultant deformed ROIs were compared with manually contoured reference ROIs using similarity coefficient metrics (i.e. Dice similarity coefficient) and surface distance metrics (i.e. 95% maximum Hausdorff distance). Non-parametric Steel test with control was used to compare different DIR algorithms to rigid registration (RIR) with post hoc Wilcoxon rank test for stratified metric comparison. A total of 2720 anatomic and 50 tumor/nodal ROIs were delineated. All DIR algorithms showed improved performance over RIR for both anatomic and target ROIs conformance as shown for the majority of comparison metrics (Steel test, p-value <0.008 after Bonferroni correction). The performance of different algorithms varied substantially with stratification by specific anatomic structures/category, and SimCT image slice thickness. Development of a formal ROI-based QA workflow for registration assessment revealed improved performance with DIR techniques over RIR. After QA, DIR implementation should be the standard for head and neck DxCT-SimCT allineation, especially for target delineation.
登录
查看更多内容
影响因子:
3.1
作者:
Noe, Karsten Ostergaard;De Senneville, Baudouin Denis;Sorensen, Thomas Sangild
通讯作者:
Sorensen, Thomas Sangild
影响因子:
3.3
作者:
Awan, Musaddiq;Kalpathy-Cramer, Jayashree;Fuller, Clifton D.
通讯作者:
Fuller, Clifton D.
DOI:
10.1186/1748-717x-7-90
发表时间:
2012-06-15
期刊:
Radiation oncology (London, England)
影响因子:
--
作者:
Hardcastle N;Tomé WA;Cannon DM;Brouwer CL;Wittendorp PW;Dogan N;Guckenberger M;Allaire S;Mallya Y;Kumar P;Oechsner M;Richter A;Song S;Myers M;Polat B;Bzdusek K
通讯作者:
Bzdusek K
影响因子:
5.7
作者:
Castadot, Pierre;Lee, John Aldo;Gregoire, Vincent
通讯作者:
Gregoire, Vincent
DOI:
10.1016/j.ejmp.2013.09.001
发表时间:
2014-05-01
影响因子:
3.4
作者:
Huger, S.;Graff, P.;Noel, A.
通讯作者:
Noel, A.