OXYGEN TENSION UNDER AN OXYGEN‐PERMEABLE CONTACT LENS*
OXYGEN TENSION UNDER AN OXYGEN‐PERMEABLE CONTACT LENS*
复制标题
透氧隐形眼镜下的氧张力*
DOI:
10.1097/00006324-197107000-00001
复制
发表时间:
1971
影响因子:
1.4
通讯作者:
R. St Helen
中科院分区:
文献类型:
--
作者:
I. Fatt;R. St Helen
&NA; The oxygen tension at the anterior corneal surface under an oxygen‐permeable contact lens is shown to be a function of the oxygen transmissibility and the thickness of the lens. The oxygen transmissibilities of several gel contact lenses and a silicone rubber lens are reported together with the procedure for making this measurement. Several of the lenses are shown to give, for an open eye, an oxygen tension at the corneal surface sufficient for maintenance of normal corneal thickness. None of the lenses tested will do this for the closed eye.