STUDY ON SEISMIC PERFORMANCE OF R/C WALL-FRAME STRUCTURES BASED ON LARGE-SCALE SHAKING TABLE TEST
STUDY ON SEISMIC PERFORMANCE OF R/C WALL-FRAME STRUCTURES BASED ON LARGE-SCALE SHAKING TABLE TEST
复制标题
基于大型振动台试验的遥控墙框架结构抗震性能研究
DOI:
10.3130/aijs.73.95
复制
发表时间:
2008
期刊:
影响因子:
--
通讯作者:
T. Kabeyasawa
中科院分区:
文献类型:
--
作者:
T. Matsumori;K. Shirai;T. Kabeyasawa
The Response of reinforced concrete wall-frame structures subjected to earthquake motion was investigated by testing a full-scale six-story specimen on the world's largest tri-axial shaking table “E-Defense”. The test specimen consisted of three parallel three-bay frames in the longitudinal direction. The central frame had a multi-story structural wall in the center bay continuous from the 1st to the 6th story. To be able to monitor shear force carried by the structural wall at the 1st story, 3-component force transducers were instrumented between foundation beams and the shaking table.The test specimen was subjected to a series of strong earthquake motions and finally nearly collapsed caused by shear failure of short columns and shear slipping failure of the structural wall at the 1st story. This paper outlines measurement plan of 3-component force transducers and also examines the shaking table test results for rigidity at the bottom of the wall, restoring force characteristics of the structure, and measured shear force carried by the 1st-story structural wall.