Importance of soil cover box area for the determination of N2O emissions from arable soils
Importance of soil cover box area for the determination of N2O emissions from arable soils
复制标题
DOI:
10.1007/bf00012052
复制
发表时间:
1996-04-01
期刊:
影响因子:
4.9
通讯作者:
Heinemeyer, O
中科院分区:
文献类型:
--
作者:
Kaiser, EA;Munch, JC;Heinemeyer, O
Five soil cover box systems varying in area were used to measure the N2O emissions from four arable soils. The covered area of the systems ranged from 78 to 576000 cm(2). The observed N2O emission rates were approximately log-normal distributed. The greatest influence of variation of N2O emission rates could be attributed to the factor sampling date/time.The different soil cover box systems were assessed by comparing measured mean N2O releases, their time courses and spatial variation. The spatial coefficient of variation of N2O emission rates decreased logarithmically with an increasing radius of the soil cover box system used.