Improvements to our laser ion source [1] have enabled us to increase its performance considerably. The components of the whole system are: A Nd: YAG laser, the source chamber and a Van de Graaff. The major changes were:1.1.|A more powerful laser.2.2.|An improved extraction system.With these modifications we have observed charge states up to 14+(measured by time of flight). Ion currents in the range of one ampere could be measured directly outside the source. Applying a pulsed extraction voltage decreased the pulse length for one charge state down to ∼ 0.4 μs FWHM.