Low-Dose 3D Time-Resolved Magnetic Resonance Angiography (MRA) of the Supraaortic Arteries: Correlation With High Spatial Resolution 3D Contrast-Enhanced MRA

Low-Dose 3D Time-Resolved Magnetic Resonance Angiography (MRA) of the Supraaortic Arteries: Correlation With High Spatial Resolution 3D Contrast-Enhanced MRA
复制标题

DOI:
10.1002/jmri.22396
复制
发表时间:
2011-01-01
影响因子:
4.4
通讯作者:
Kim, Bum-Soo
Kim, Bum-Soo
中科院分区:
医学2区
文献类型:
--
作者:
Lee, Youn-Joo;Laub, Gerhard;Kim, Bum-Soo

文献摘要

被引文献

相似文献

目的:评价低剂量、3D时间分辨对比增强磁共振血管造影(TR-CEMRA)评估主动脉上血管的可行性,并与高分辨率对比增强MRA(HR-CEMRA)的结果进行比较。材料和方法:这是一项机构审查委员会批准的回顾性研究。45名连续患者在3.0 T下接受了对比增强3D TR-CEMRA和3D HR-CEMRA,以评价神经血管疾病。对于TR-CEMRA,以1 mL的恒定剂量给予钆布醇(与患者体重无关),对于HR-CEMRA,以0.1 mmol/kg的恒定剂量给予钆布醇。两名读者评价图像质量使用四点量表(从0 =优秀到3 =非诊断),并随后将每个狭窄分为临床相关类别:正常(0%),轻度狭窄(50%),occlusion.Results:低剂量TR-CEMRA的整体图像质量是在诊断范围(中位数0,范围03)。关于狭窄的分级。TWIST序列TR-CEMRA与HR-CEMRA相关(r = 0.668,P < 0.001)。就TR-CEMRA与HR-CEMRA的比较而言,在评价狭窄或闭塞的675个主动脉上动脉节段中,611个节段的结果一致(90.5%),高估41/675(6.1%),低估23 675(3.4%)。通过给予小剂量造影剂(1 cc)实现TR-CEMRA在主动脉上的评价中产生快速和重要的功能和解剖信息。由于空间分辨率有限,与HR-CEMRA相比,TR-CEMRA在当前参数下倾向于高估较小颅内动脉的狭窄。
Purpose: To evaluate the feasibility of low-dose, 3D time-resolved contrast-enhanced magnetic resonance angiography (TR-CEMRA) in the assessment of the supraaortic vessel, and to compare the results with high-resolution contrast-enhanced MRA (HR-CEMRA).Materials and Methods: This was an Institutional Review Board-approved retrospective study. Forty-five consecutive patients underwent contrast-enhanced 3D TR-CEMRA and 3D HR-CEMRA for evaluation of neurovascular disease at 3.0 T. Gadobutrol was administered at a constant dose of 1 mL for TR-CEMRA (independent of patient weight), and 0.1 mmol/kg for HR-CEMRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = nondiagnostic), and subsequently graded each stenosis into clinically relevant categories: normal (0%), mild stenosis (50%), and occlusion.Results: The overall image quality for low-dose TR-CEMRA was in the diagnostic range (median 0, range 03). On the grading of stenosis. TR-CEMRA using the TWIST sequence correlated with HR-CEMRA (r = 0.668, P < 0.001). In terms of the comparison of TR-CEMRA with HR-CEMRA, of the 675 supraaortic arterial segments evaluated for stenosis or occlusion, agreement occurred in 611 of 675 (90.5%), overestimation in 41 of 675 (6.1%), and underestimation 23 of 675 (3.4%).Conclusion: TR-CEMRA achieved by administration of a small contrast dose (1 cc) yields rapid and important functional and anatomical information in the evaluation of supraaortic arteries. Due to limited spatial resolution, TR-CEMRA at the current parameters has a tendency to overestimate the stenosis of smaller intracranial arteries compared to HR-CEMRA.