The effects of dielectric shield on specific absorption rate and heat transfer in the human body exposed to leakage microwave energy
The effects of dielectric shield on specific absorption rate and heat transfer in the human body exposed to leakage microwave energy
复制标题
介电屏蔽对暴露于泄漏微波能量的人体比吸收率和传热的影响
DOI:
10.1016/j.icheatmasstransfer.2010.12.004
复制
发表时间:
2011
影响因子:
7
通讯作者:
P. Rattanadecho
中科院分区:
文献类型:
--
作者:
T. Wessapan;Siramate Srisawatdhisukul;P. Rattanadecho
This paper proposes a numerical study to simulate the effects of dielectric shield on the specific absorption rate (SAR) and the temperature increase in the human body exposed to leakage microwave energy. In this study, the effects of shield dielectric properties on distributions of SAR and temperature increase within the human body at various operating frequency are systematically investigated. Based on the obtained results, the installed dielectric shield strongly affects the SAR and the temperature increase in human body. The SAR and the temperature increase in human body can be reduced simultaneously by setting the appropriate dielectric properties of the dielectric shield. The appropriate dielectric properties of the dielectric shield greatly depend on the operating frequencies. These fundamental data for the implementations of the radiation protection shielding materials, with focusing on the human organism, are provided as well.