Parameters of acoustic emission test of concrete under static uniaxial tension
Parameters of acoustic emission test of concrete under static uniaxial tension
复制标题
混凝土单轴静拉声发射试验参数
DOI:
--
复制
发表时间:
2011
期刊:
影响因子:
--
通讯作者:
Shen, De-Jian1
中科院分区:
文献类型:
--
作者:
Wu, Sheng-Xing1;Wang, Yan1;Li, Jia1;Shen, De-Jian1
Setting of hardware parameters,filtering parameters for acoustic emission(AE) acquiring system,and AE parameters as well as their correlations were studied systematically with tests,11 groups of pensile lead break tests and 13 concrete specimens loaded in uniaxial tension were carried out.Feature parameters and waveforms of AE signals acquired by 3 kinds of sensors during the processes of tests were stored using a digital parameter-waveform collecting system.The test data were analyzed using the parameter combined with waveform method and the post-extracting technique for waveforms.The results showed that there are reasonable values for gain of preamplifier,threshold,sampling rate,sampling length and parameters of band pass filter;amplitude,count,duration,AE signal energy,absolute energy and signal strength are suitable for evaluating the phased damage feature of concrete under uniaxial tension loading;the significant correlations among amplitude,count,duration,rise time and signal strength are found.The study results provided a reference for studying on concrete failure process using AE technology.