Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0

Response of the FAst TIMing Array (FATIMA) for DESPEC at FAIR Phase-0
复制标题

DOI:
10.1016/j.nima.2023.168597
复制
发表时间:
2023-09
期刊:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
影响因子:
--
通讯作者:
M. Chishti;S. Jazrawi;R. Shearman;P. Regan;Z. Podolyák;S.M. Collins;M. Gorska;B. Cederwall;A. Yaneva;G.X. Zhang;J. Cederkall;A. Goasduff;H. Albers;S. Alhomaidhi;A. Banerjee;A. Bruce;G. Benzoni;B. Das;T. Davinson;L. Fraile;J. Gerl;G. Häfner;J. Jolie;N. Hubbard;P. John;R. Lozeva;A. K. Mistry;B.S. Nara Singh;M. Mikołajczuk;M. Polettini;N. Pietralla;J. Régis;M. Rudigier;E. Sahin;Aayushman Sharma;M. Si;J. Vesic;V. Werner
M. Chishti;S. Jazrawi;R. Shearman;P. Regan;Z. Podolyák;S.M. Collins;M. Gorska;B. Cederwall;A. Yaneva;G.X. Zhang;J. Cederkall;A. Goasduff;H. Albers;S. Alhomaidhi;A. Banerjee;A. Bruce;G. Benzoni;B. Das;T. Davinson;L. Fraile;J. Gerl;G. Häfner;J. Jolie;N. Hubbard;P. John;R. Lozeva;A. K. Mistry;B.S. Nara Singh;M. Mikołajczuk;M. Polettini;N. Pietralla;J. Régis;M. Rudigier;E. Sahin;Aayushman Sharma;M. Si;J. Vesic;V. Werner
中科院分区:
其他
文献类型:
--
作者:
M. Chishti;S. Jazrawi;R. Shearman;P. Regan;Z. Podolyák;S.M. Collins;M. Gorska;B. Cederwall;A. Yaneva;G.X. Zhang;J. Cederkall;A. Goasduff;H. Albers;S. Alhomaidhi;A. Banerjee;A. Bruce;G. Benzoni;B. Das;T. Davinson;L. Fraile;J. Gerl;G. Häfner;J. Jolie;N. Hubbard;P. John;R. Lozeva;A. K. Mistry;B.S. Nara Singh;M. Mikołajczuk;M. Polettini;N. Pietralla;J. Régis;M. Rudigier;E. Sahin;Aayushman Sharma;M. Si;J. Vesic;V. Werner

文献摘要

相似文献

35.介绍了格尔-38慕尼黑达姆施塔特FAIR Phase-0设施DECay SPECTroscopy(DE-37 SPEC)实验系统中使用的FASt TIMing 36阵列(法蒂玛)的γ射线探测的蒙特-卡罗模拟响应。在这种配置中,法蒂玛由36个LaBr 3(Ce)39探测器组成,围绕AIDA,位置敏感带电粒子主动停止-每40个。在FAIR-0设施的第一个DESPEC实验中测量的96 Pd中I π= 8+异构体馈送衰变级联的衰变被用于验证42个模拟。实验结果表明,法蒂玛在106、325、684、44和1415 keV处的全能量峰值效率分别为11.2(11)%、6.8(7)%、3.8(4)%和2.1(4)%,与模拟的45响应值一致。46
35 The Monte-Carlo simulated response for γ-ray detection of the FAst TIMing 36 Array (FATIMA) for exploitation within the the DEcay SPECtroscopy (DE-37 SPEC) experimental system at the FAIR Phase-0 facility at Darmstadt, Ger-38 many is presented. In this configuration, FATIMA consisted of 36 LaBr 3 (Ce) 39 detectors surrounding the AIDA, position sensitive charged-particle active stop-40 per. The decay of the I π= 8+ isomer-fed decay cascade in 96 Pd, measured in 41 the first DESPEC experiment at the FAIR-0 facility was used to validate the 42 simulations. The experimental data yielded in-situ full-energy peak efficiency 43 values for FATIMA of 11.2 (11)%, 6.8 (7)%, 3.8 (4)% and 2.1 (4)% at 106, 325, 684 44 and 1415 keV respectively, consistent with the values derived from the simulated 45 response. 46