Noncontact Ultrasonic Transport of Liquid Using a Flexural Vibration Plate
Noncontact Ultrasonic Transport of Liquid Using a Flexural Vibration Plate
复制标题
DOI:
10.1143/apex.5.097301
复制
发表时间:
2012-09-01
影响因子:
2.3
通讯作者:
Nakamura, Kentaro
中科院分区:
文献类型:
--
作者:
Ding, Mingjie;Koyama, Daisuke;Nakamura, Kentaro
We have succeeded in the noncontact transportation of ethanol droplets inside a semi cylindrical acoustic waveguide. The waveguide was composed of a vibration bottom plate and a semi cylindrical reflector, and a propagating acoustic field was excited in the waveguide. The droplet was levitated at the nodal position of the standing wave mode in the cross section of the waveguide and transported by the traveling wave component in the horizontal direction. The transportation distance was 65mm and the terminal velocity reached 2.3 m/s when the droplet was 1.5mm in diameter and 1.38 g in weight. (C) 2012 The Japan Society of Applied Physics