DIRECT RADIOIMMUNOASSAY OF ATRIAL NATRIURETIC FACTOR
DIRECT RADIOIMMUNOASSAY OF ATRIAL NATRIURETIC FACTOR
复制标题
DOI:
10.1016/s0006-291x(84)80074-1
复制
发表时间:
1984-01-01
影响因子:
3.1
通讯作者:
GENEST, J
中科院分区:
文献类型:
--
作者:
GUTKOWSKA, J;THIBAULT, G;GENEST, J
A direct radioimmunoassay of atrial natriuretic factor (ANF) was developed. The method uses a synthetic 26 amino-acid fragment (8-33 ANF) of the native peptide. Antibodies have been prepared in rabbits immunized with the peptide coupled to thyroglobulin. The radiolabeled tracer prepared by iodination according to the Chloramine-T method has been purified by HPLC [high performance liquid chromatography] followed by affinity chromatography on Sepharose-4B anti-ANF. Dextran-coated charcoal has been used for separation of free from antibody bound radioactivity. Higher ANF content was found in the right rat atrium than in the left. These results have confirmed by bioassay.