Harmonic current reduction control of IPMSM drive inverter without inductor or electrolytic capacitor
Harmonic current reduction control of IPMSM drive inverter without inductor or electrolytic capacitor
复制标题
无电感、电解电容的IPMSM驱动逆变器谐波电流抑制控制
DOI:
10.1109/iecon.2016.7793203
复制
发表时间:
2016
期刊:
影响因子:
--
通讯作者:
Y. Yokokura
中科院分区:
文献类型:
--
作者:
K. Abe;K. Ohishi;H. Haga;Y. Yokokura
In a single-phase to three-phase inverter that does not have an inductor or electrolytic capacitor, the inverter must control not only the motor but also the input power factor because there is no power factor correction circuit or energy buffer. To improve the input power factor, several control methods are proposed. However, if the motor has large spatial harmonics caused by the rotor structure, the bandwidth limitations of the control system adversely affect the source current response and thereby cause source current harmonics. This paper proposes a harmonic current reduction controller that makes it possible to obtain a sinusoidal source current. The proposed controller focuses on the relationship between the source current and the average DC-link current and controls the source current using a feedforward control method. The effectiveness of the proposed method is experimentally verified.