RADIATION SPECTRA FOR AUGER-ELECTRON EMITTING RADIONUCLIDES - REPORT NO 2 OF AAPM-NUCLEAR-MEDICINE-TASK-GROUP NO 6
RADIATION SPECTRA FOR AUGER-ELECTRON EMITTING RADIONUCLIDES - REPORT NO 2 OF AAPM-NUCLEAR-MEDICINE-TASK-GROUP NO 6
复制标题
DOI:
10.1118/1.596927
复制
发表时间:
1992-11-01
期刊:
影响因子:
3.8
通讯作者:
HOWELL, RW
中科院分区:
文献类型:
--
作者:
HOWELL, RW
Radiation spectra for radionuclides currently provided by the MIRD Committee and ICRP do not include the very low-energy N- and O-shell Auger electrons. These electrons, emitted in large numbers by radionuclides decaying by electron capture and/or internal conversion, are important for determining the absorbed dose in microscopic volumes. Accordingly, the present AAPM Report employs Monte Carlo computational methods to obtain a self-consistent set of complete radiation spectra for a variety of radionuclides including Fe-55, Ga-67, Tc-99m, In-111, In-113m, In-115m, I-123, I-125, Pt-195m, Pt-195m, Ti-201, and Pb-203. Although the conventional spectra provided by MIRD and ICRP are adequate for most dosimetry calculations, the Auger electron spectra provided in this report are recommended for calculating the dose to target volumes < 1 mum in diameter.