Space Thermometry Using a Double Acoustic Delay Line Oscillator
Space Thermometry Using a Double Acoustic Delay Line Oscillator
复制标题
使用双声延迟线振荡器进行空间测温
DOI:
10.1143/jjap.39.3103
复制
发表时间:
2000
期刊:
影响因子:
--
通讯作者:
K. Nagai
中科院分区:
文献类型:
--
作者:
K. Mizutani;E. Ishikawa;K. Nagai
Acoustic thermometry in space using a double-delay line oscillator is described. The delay line oscillator is an important component in the sensor systems. In this paper, the adverse effect of a discontinuous oscillation was solved by adopting an acoustic technique which uses multiple oscillators. An experimental result at 40 kHz shows that the error in measured room temperature is 1.5% in a room 4,020 mm (D)×4,200 mm (W)×3,550 mm (H) with air conditioning. The acoustic thermometry proposed in this paper has advantages over conventional methods for such applications as atmospheric monitoring and air conditioning.