Refined Balloon Pulmonary Angioplasty in Chronic Thromboembolic Pulmonary Hypertension: Initial Results of U.S. Regional Program.
Refined Balloon Pulmonary Angioplasty in Chronic Thromboembolic Pulmonary Hypertension: Initial Results of U.S. Regional Program.
复制标题
慢性血栓栓塞性肺动脉高压的改良球囊肺血管成形术:美国区域计划的初步结果。
DOI:
10.1016/j.jacadv.2023.100291
复制
发表时间:
2023
期刊:
影响因子:
--
通讯作者:
Forfia,Paul
中科院分区:
文献类型:
--
作者:
Bashir,Riyaz;Noory,Ali;Oliveros,Estefania;Romero,Carlos;Maruthi,Rohit;Mirza,Arslan;Lakhter,Vladimir;Zhao,Huaqing;Brisco-Bacik,Meredith;Vaidya,Anjali;Auger,WilliamR;Forfia,Paul
BackgroundBalloon pulmonary angioplasty (BPA) is rapidly evolving therapeutic option for patients with nonsurgical chronic thromboembolic pulmonary hypertension (CTEPH). There are few U.S. studies that have reported on the outcomes of this novel therapeutic option.ObjectivesThe authors sought to evaluate the efficacy and safety of refined BPA in the treatment of patients with CTEPH.MethodsThis is a retrospective study of CTEPH patients that underwent BPA. The primary efficacy endpoint was the change in pulmonary vascular resistance after BPA as compared to baseline and the primary safety endpoint was the rate of hemoptysis within 24 hours. Secondary endpoints included death, World Health Organization functional class, and 6-minute walk distance. Logistic regression was used to evaluate factors associated with a hemodynamic and functional response.ResultsA total of 211 BPA sessions were performed on 77 patients (average 2.7 ± 1.7 sessions/patient). After BPA the mean pulmonary vascular resistance improved by 26% (6.5 ± 3.4 WU to 4.8 ± 2.9 WU,P< 0.001). The mean 6-minute walk distance improved by 71.7 m (P< 0.001), and WHO functional class improved by 1 functional class (P< 0.001). There was one death related to reperfusion lung injury. Ten sessions (4.7%) were complicated by hemoptysis. Independent factors associated with improved functional and hemodynamic response included preprocedural use of riociguat, reduce baseline PA compliance, and >3 BPA sessions/patient.ConclusionsThis single center study from the United States showed that BPA with refined techniques in patients with CTEPH was relatively safe and was associated with significant improvements in pulmonary hemodynamics and functional capacity.
登录
查看更多内容
DOI:
--
发表时间:
1986
期刊:
The Journal of biological chemistry
影响因子:
--
作者:
Bishop,WR;Bell,RM
通讯作者:
Bell,RM
影响因子:
3.5
作者:
M. Simon;H. Chap;L. Douste‐Blazy
通讯作者:
L. Douste‐Blazy
影响因子:
4.1
作者:
K. Authi;N. Crawford
通讯作者:
N. Crawford
影响因子:
4.8
作者:
M. Billah;E. Lapetina
通讯作者:
E. Lapetina
影响因子:
4.8
作者:
L. Brass;S. Joseph
通讯作者:
S. Joseph