一名49岁的女性患有一个小的囊状动脉瘤,用Guglielmi可解脱弹簧圈(GDC)不完全闭塞。她在治疗后42天死于另一个动脉瘤破裂。栓塞动脉瘤的尸检显示动脉瘤瘤颈处没有新生内皮,但观察到局限于动脉瘤腔外周的机化血栓。虽然动脉瘤的隔离不明显,但用这种方法进行的松散栓塞可能有助于加强动脉瘤壁。
A 49-year-old woman had a small saccular aneurysm that was incompletely occluded with a Guglielmi detachable coil (GDC). She died from rupture of another aneurysm 42 days after the treatment. Autopsy for the embolized aneurysm revealed no neoendothelium at the aneurysmal neck, but an organized thrombus was observed limited to the periphery of the aneurysmal lumen. Although isolation of the aneurysm was not apparent, loose embolization with this method may help to reinforce the aneurysmal wall.