1-km beamline at SPring-8

1-km beamline at SPring-8
复制标题

SPring-8 的 1 公里光束线

DOI:
10.1117/12.411621
复制
发表时间:
2001
期刊:
--
影响因子:
--
通讯作者:
T. Ohata
T. Ohata
中科院分区:
--
文献类型:
--
作者:
T. Ishikawa;K. Tamasaku;M. Yabashi;S. Goto;Y. Tanaka;H. Yamazaki;K. Takeshita;H. Kimura;H. Ohashi;T. Matsushita;T. Ohata

文献摘要

被引文献

相似文献

一条一公里长的同步辐射光束线和一个X射线波动器源已于春秋八号完成。计划中的光束线是为了促进广域相干X射线束的各种应用,开发用于重力红移测量的双晶X射线干涉仪,以及开发高灵敏度的加速器动力学诊断方法。本文报道了长光束线的结构以及一些选定的初步结果,包括相衬成像和衍射成像的应用。
A one-kilometer long synchrotron radiation beamline with an x- ray undulator source was completed at SPring-8. The beamline was planned to facilitate various applications of a wide-area coherent x-ray beam, development of bi-crystal x-ray interferometers for gravitational red-shift measurement and development of highly sensitive diagnostic methods of accelerator dynamics. This paper reports the structure of the long beamline as well as some selected first results including phase contrast imaging and diffraction imaging applications.