Thrombelastgram as a hemostatic monitor during recombinant factor VIIa treatment in hemophilia A patients with inhibitor to factor VIII.

Thrombelastgram as a hemostatic monitor during recombinant factor VIIa treatment in hemophilia A patients with inhibitor to factor VIII.
复制标题

血栓弹力图作为凝血因子 VIIa 治疗期间具有因子 VIII 抑制剂的甲型血友病患者的止血监测仪。

DOI:
10.1159/000217256
复制
发表时间:
1996
期刊:
Haemostasis
影响因子:
--
通讯作者:
M. Shima
M. Shima
中科院分区:
--
文献类型:
--
作者:
Akira Yoshioka;K. Nishio;M. Shima

文献摘要

被引文献

相似文献

血栓弹力图 (TEG) 是一种古老但自动化的仪器,可显示血液凝固和纤维蛋白溶解过程中发生的变化。在 3 名具有高滴度凝血因子 VIII 抑制剂的 A 型血友病患者中使用重组凝血因子 VIIa (65-80 μg/kg) 时,TEG 被评估为优于活化部分凝血活酶时间 (APTT) 作为止血效果的监测指标。 TEG比APTT更合适,因为TEG的r、r+k和ma值在输注后至少4小时内归一化,而APTT不同程度地缩短并且并不总是维持在正常水平达4小时。
Thrombelastgram (TEG) is an old but automated instrument that demonstrates changes occurring during blood coagulation and fibrinolysis. TEG was evaluated to be better than activated partial thromboplastin time (APTT) as a monitor of hemostatic effects when using recombinant factor VIIa (65-80 mu g/kg) in 3 hemophilia A patients with a high titer of factor VIII inhibitors. TEG was more suitable than APTT, because r, r + k and ma values of TEG were normalized at least for 4 h after the infusion, whereas APTT was variably shortened and was not always maintained at a normal level for 4 h.