Employing a Cerenkov detector for the thickness measurement of X-rays in a scattering background
Employing a Cerenkov detector for the thickness measurement of X-rays in a scattering background
复制标题
使用切伦科夫探测器测量散射背景中 X 射线的厚度
DOI:
10.1088/1674-1137/34/12/020
复制
发表时间:
2010
影响因子:
3.6
通讯作者:
Zhang Qing-Jun
中科院分区:
文献类型:
--
作者:
Li Shu-Wei;Kang Ke-Jun;Wang Yi;Li Jin;Li Yuan-Jing;Zhang Qing-Jun
The variation in environmental scattering background is a major source of systematic errors in X-ray inspection and measurement systems. As the energy of these photons consisting of environmental scattering background is much lower generally, the Cerenkov detectors having the detection threshold are likely insensitive to them and able to exclude their influence. A thickness measurement experiment is designed to verify the idea by employing a Cerenkov detector and an ionizing chamber for comparison. Furthermore, it is also found that the application of the Cerenkov detectors is helpful to exclude another systematic error from the variation of low energy components in the spectrum incident on the detector volume.