Design of a clinical event monitor.
Design of a clinical event monitor.
复制标题
DOI:
10.1006/cbmr.1996.0016
复制
发表时间:
1996-06
期刊:
影响因子:
--
通讯作者:
George Hripczak;P. Clayton;R. Jenders;J. Cimino;Stephen B. Johnson
中科院分区:
文献类型:
--
作者:
George Hripczak;P. Clayton;R. Jenders;J. Cimino;Stephen B. Johnson
The issues and implementation of a clinical event monitor are described. An event monitor generates messages for providers, patients, and organizations based on clinical events and patient data. For example, an order for a medication might trigger the generation of a warning about a drug interaction. A model based on the active database literature has as its main components an event (which triggers a rule to fire), a condition (which tests whether an action ought to be performed), and an action (often the generation of a message). The details of implementing such a monitor are described, using as an example the Columbia-Presbyterian Medical Center clinical event monitor, which is based on the Arden Syntax for Medical Logic Modules.