Development of a Micro-PIXE Camera

Development of a Micro-PIXE Camera
复制标题

Micro-PIXE 相机的开发

DOI:
10.1142/s0129083598000236
复制
发表时间:
1998
期刊:
International Journal of PIXE
影响因子:
--
通讯作者:
R. Tanaka
R. Tanaka
中科院分区:
--
文献类型:
--
作者:
S. Matsuyama;K. Ishii;A. Sugimoto;T. Satoh;K. Gotoh;H. Yamazaki;S. Iwasaki;K. Murozono;J. Inoue;T. Hamano;S. Yokota;T. Sakai;T. Kamiya;R. Tanaka

文献摘要

被引文献

相似文献

我们在日本原子能研究所(JAERI)的高崎先进辐射应用离子加速器(TIARA)分部研制了一套μ-PIXE分析系统。在500 μm × 500 μm范围内进行元素分析,空间分辨率< 0.3 μm,即使在测量过程中,多元素分布也以图像形式显示在计算机显示器上。我们称这个系统为微型PIXE相机。
We developed a system of μ-PIXE analysis at the division of Takasaki ion accelerator for advanced radiation application (TIARA) in Japan Atomic Energy Research Institute (JAERI), which consists of a microbeam apparatus, a multi-parameter data acquisition system and a personal computer. Elemental analysis in the region of 500 μm × 500 μm can be performed with a spatial resolution of < 0.3 μm and multi-elemental distributions are presented as images on a computer display even during measurement. We call this system a micro-PIXE camera.