Insufficient cure under the condition of high irradiance and short irradiation time
Insufficient cure under the condition of high irradiance and short irradiation time
复制标题
DOI:
10.1016/j.dental.2008.07.007
复制
发表时间:
2009-03-01
期刊:
影响因子:
5
通讯作者:
Suh, Byoung I.
中科院分区:
文献类型:
--
作者:
Feng, Li;Carvalho, Ricardo;Suh, Byoung I.
Objectives. To investigate if and why a plasma arc curing (PAC) light tends to undercure methacrylate-based resins or resin composites.Methods. Model dimethacrylate resins, commercial dental adhesives, and commercial resin composites were cured using a PAC light and a halogen light with the similar radiant exposures but different combinations of irradiance and irradiation time. The degree of double bond conversion (DC) was measured with FTIR spectroscopy and analyzed as a function of radiant exposure.Results. The PAC light produced a lower DC than the halogen light for the model resin with the lowest viscosity and for three of the four adhesives. With a high irradiance, the PAC light could cure three of the four composites as thoroughly as its halogen counterpart. When the irradiance was reduced, however, three composites yielded a lower DC.Conclusions. insufficient cure by PAC lights or any curing lights with very high irradiance is likely to happen when too short an irradiation time is used. It is because under higher irradiance, the lifetime of free radicals is shorter. (C) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.