Bi-2223 Test Coils for High Resolution NMR Magnets.
Bi-2223 Test Coils for High Resolution NMR Magnets.
复制标题
用于高分辨率 NMR 磁体的 Bi-2223 测试线圈。
DOI:
10.1109/tasc.2017.2652378
复制
发表时间:
2017
期刊:
影响因子:
--
通讯作者:
White,JM
中科院分区:
文献类型:
--
作者:
Marshall,WS;Bird,MD;Godeke,A;Larbalestier,DC;Markiewicz,WD;White,JM
Recently, significant improvement in the strain tolerance of Bi-2223 conductor has been achieved by lamination with high strength nickel alloy. The conductor, supplied by Sumitomo Electric and designated Type HT-NX, is now commercially available in lengths sufficient for manufacture of high-homogeneity solenoids. A program to fully exploit the improved conductor properties is now underway at the National High Magnetic Field Laboratory (NHMFL). Five coils are being made, the last of which is to demonstrate an NMR measurement approaching 1 GHz and 1 ppm over 10-mm volume. In so doing, we expect to demonstrate critical current fraction, and strain similar to that expected in 30-T NMR magnets. The coils will be tested inside an existing 16 Tesla large-bore background magnet at the NHMFL. The design of the NMR demonstration coil is presented first, with expected values for field, homogeneity, and strain given. A technology development program is then outlined, which includes fabrication of four test coils to test various design features, develop fabrication tooling, and train personnel.