增量式Σ-Δ(I <$Δ)模数转换器(ADC)本质上是具有周期性复位功能的<$Δ ADC,非常适合低功耗低速生物传感器应用。近年来,人们一直在探索连续时间(CT)I <$Δ ADC在功耗方面的潜在优势。本文分析了反馈型数模转换器(DAC)对CT I Δ ADC性能的影响。首先分析了不同的反馈DAC方案,然后将其应用于三阶单位CT I/Δ ADC中进行评估。仿真结果表明,该方案在时序误差敏感性和功耗之间取得了较好的平衡,为选择低功耗反馈DAC方案提供了参考。
Incremental sigma-delta (IΣΔ) analog-to-digital converters (ADCs), which are essentially ΣΔ ADCs with periodic resetting, are well suited for low-power low-speed biosensor applications. In recent years, the potential advantage in terms of power dissipation of continuous-time (CT) IΣΔ ADCs have been explored. This paper analyzes the impact of feedback digital-to-analog converters (DACs) on the performance of CT IΣΔ ADCs. Different feedback DAC schemes are firstly analyzed and then evaluated by employing them in a 3rd order single-bit CT IΣΔ ADC. Simulation results are discussed considering the trade-off between the timing error sensitivity and the power consumption, thereby offering a reference for selecting a power efficient feedback DAC scheme.