Laser ablation comparison by picosecond pulses train and nanosecond pulse

Laser ablation comparison by picosecond pulses train and nanosecond pulse
复制标题

DOI:
10.1088/1612-2011/12/12/126001
复制
发表时间:
2015-10
影响因子:
1.7
通讯作者:
V. N. Lednev;M. N. Filippov;A. F. Bunkin;S. M. Pershin
V. N. Lednev;M. N. Filippov;A. F. Bunkin;S. M. Pershin
中科院分区:
物理与天体物理4区
文献类型:
--
作者:
V. N. Lednev;M. N. Filippov;A. F. Bunkin;S. M. Pershin

文献摘要

被引文献

相似文献

通过一系列皮秒脉冲和纳秒脉冲的激光烧蚀的比较,揭示了激光坑、烧蚀阈值、等离子体尺寸和谱线强度的差异。激光烧蚀与皮秒脉冲的火车导致改善的火山口的质量,而烧蚀的质量下降了30%。观察到皮秒序列烧蚀的激光等离子体尺寸减小,而等离子体光谱中的原子/离子线的强度大2-4倍,表明等离子体中的激发和原子化得到改善。
A comparison of laser ablation by a train of picosecond pulses and nanosecond pulses revealed a difference in laser craters, ablation thresholds, plasma sizes and spectral line intensities. Laser ablation with a train of picosecond pulses resulted in improved crater quality while ablated mass decreased up to 30%. A reduction in laser plasma dimensions for picosecond train ablation was observed while the intensity of atomic/ionic lines in the plasma spectra was greater by a factor of 2–4 indicating an improved excitation and atomization in the plasma.