In-situ health monitoring of a bonded composite patch using the strain ratio technique
In-situ health monitoring of a bonded composite patch using the strain ratio technique
复制标题
使用应变比技术对粘合复合材料补片进行原位健康监测
DOI:
10.1117/12.420878
复制
发表时间:
2001
期刊:
影响因子:
--
通讯作者:
A. Baker
中科院分区:
文献类型:
--
作者:
S. Moss;S. Galea;I. Powlesland;M. Konak;A. Baker
Piezo-electric (PVDF) sensors were applied to a specifically prepared two-sided composite specimen. The specimen was fatigued with a 3Hz cyclic load until the adhesive bond between composite patch and aluminium failed. During the cyclic loading period the output from the PVDF sensors were monitored by a prototype "Smart Patch Device". The Smart Patch Device measured outputs from two PVDF sensors, one on the "patch" and one in the "far-field" from which was calculated a "Patch state of health". The Smart Patch Device successfully detected the composite patch disbonding from the aluminium. The effect of the adhesive spew fillet, which can produce significant strains in disbonded sections of patch, is considered. Finally a number of points in relation to the use of the strain ratio technique for patch state of health monitoring are elucidated..