Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine Systems
Open-Switch Fault Detection Method of a Back-to-Back Converter Using NPC Topology for Wind Turbine Systems
复制标题
DOI:
10.1109/tia.2014.2327151
复制
发表时间:
2015
影响因子:
4.4
通讯作者:
June-Seok Lee;Kyo-Beum Lee;F. Blaabjerg
中科院分区:
文献类型:
--
作者:
June-Seok Lee;Kyo-Beum Lee;F. Blaabjerg
In wind turbine generation (WTG) systems, a back-to-back converter with a neutral-point-clamped (NPC) topology is widely used because this topology has more advantages than a conventional two-level topology, particularly when operating at high power. There are 12 switches in the NPC topology. An open-switch fault in the NPC rectifier of the back-to-back converter leads to the distortion of the input current and torque vibration in the system. Additionally, an open-switch fault in the NPC inverter of the back-to-back converter causes the distortion of the output current. Furthermore, the WTG system can break down in the worst case scenario. To improve the reliability of WTG systems, an open-switch fault detection method for back-to-back converters using the NPC topology is required. This study analyzes effects of inner and outer open-switch faults of the NPC rectifier and inverter and describes a novel open-switch fault detection method for all possible open-switch faults in the back-to-back converter.