采用人工传输线和双面平行带状线的小型化4:1不等威尔金森功率分配器
DOI:
10.1155/2017/6751694
复制
发表时间:
2017-01-01
影响因子:
2.2
通讯作者:
Shao, Bei
中科院分区:
文献类型:
--
作者:
Huang, Wensi;Li, Qian;Shao, Bei
A 4 : 1 unequal Wilkinson power divider using microstrip artificial transmission lines (ATLs) is proposed. For the ATL, a series of meandered-line inductors, parallel-plate capacitors, and interdigital capacitors are employed. The designed power divider is composed of three ATLs, and a method has been proposed using technology of ATLs and double-sided parallel-strip lines (DSPSLs) to design line of high characteristic impedance. Microstrip line with very high characteristic impedance of over 150 Omega has been achieved by this method, which cannot be easily achieved by conventional transmission lines because of comparably thin conductor width. The fabricated 4 : 1 unequal power divider has good operational performance and occupies 55.3 mm x 37.8 mm, which is only about 40% of area compared to a conventional one at 0.9 GHz.Background: Serum soluble lectin-like oxidized low-density lipoprotein receptor-1 (sLOX-1) has been shown associated with the progression of atherosclerosis in endothelial cells. We sought to assess whether the baseline serum sLOX-1 levels are correlated with the presence and short-term functional outcome of large-artery atherosclerotic (LAA) stroke. Methods: The study recruited 241 subjects, including 148 consecutive patients with acute ischemic stroke with the subtype of LAA and 93 non-stroke controls. Clinical and laboratory data, including serum concentration of sLOX-1, were collected within 24h of admission, and the severity of LAA stroke patients was evaluated by National Institutes of Health Stroke Scale score. And functional outcome was assessed by modified Rankin Scale three months after stroke. The association between sLOX-1 level and the functional outcome at three months was analyzed by multiple logistic regression models. Results: Serum levels of sLOX-1 in the LAA stroke patients were significantly higher as compared to normal controls (2.48 +/- 0.93 ng/ml vs. 2.22 +/- 0.79 ng/ml in the controls, t = 2.301, p = 0.022). The levels of serum sLOX-1 in patients with good outcome were significantly lower than those with poor outcome (2.39 +/- 0.94 ng/ml vs. 2.77 +/- 0.84 ng/ml, p = 0.032). After adjusting for potential confounders, sLOX-1 was still an independent predictor for the function outcome with an adjusted OR of 3.39 (95% CI, 1.61-7.11, p = 0.001). Conclusions: The serum sLOX-1 level was higher in patients with LAA stroke, and it was an independent predictor of functional outcome in patients with LAA ischemic stroke.