Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode

Infrared imaging diagnostics for parameters of powerful ion beams formed by a diode in a double-pulse mode
复制标题

DOI:
10.1109/ppc.2011.6191440
复制
发表时间:
2011-06
期刊:
2011 IEEE Pulsed Power Conference
影响因子:
--
通讯作者:
Y. Isakova
Y. Isakova
中科院分区:
其他
文献类型:
--
作者:
Y. Isakova

文献摘要

被引文献

相似文献

对吉瓦脉冲离子束参数进行红外成像诊断是一种快速控制的有效方法。它允许测量靶上的能量密度分布,优化离子二极管的操作和控制靶照射模式。空间分辨率为0.9-1 mm,标准热像仪的灵敏度在0.05J/cm2以上的能量密度下提供每个脉冲的热印记配准。
Infrared imaging diagnostics on the parameters of pulsed ion beams of gigawatt power is an effective method for rapid control. It allows for the measuring of energy density distribution at the target, optimization of an ion diode operation and control of the mode of target irradiation. Spatial resolution is of 0.9–1 mm, the sensitivity of a standard thermal camera provides registration of a thermal imprint per pulse at energy densities above 0.05 J/cm2.