Windage loss reduction study for TFTR pulse generator
Windage loss reduction study for TFTR pulse generator
复制标题
TFTR脉冲发生器风阻损失降低研究
DOI:
10.1109/fusion.1997.687822
复制
发表时间:
1997
期刊:
影响因子:
--
通讯作者:
W. J. Martin
中科院分区:
文献类型:
--
作者:
M. Awad;W. J. Martin
In PPPL's campaign to improve operating efficiency and reduce operating costs of our large vertical shaft motor generators proved to be a fruitful area. The measured losses in the stator air cooling loop were in the area of one megawatt. Reducing these losses was the focus of a recent study by PPPL and GE Hydro. Operating data was used to calculate the load cycle temperature profile of the motor generator. Based on the wide margin between design limitation and operating profile, the estimated energy saving is about 200 KW per hour. An optimum air velocity through the generator stator cooler was determined and means were developed to reduce the flow without compromising generator insulation limits.