Improved fat suppression using multipeak reconstruction for IDEAL chemical shift fat-water separation: application with fast spin echo imaging.
Improved fat suppression using multipeak reconstruction for IDEAL chemical shift fat-water separation: application with fast spin echo imaging.
复制标题
DOI:
10.1002/jmri.21664
复制
发表时间:
2009-02
影响因子:
4.4
通讯作者:
Reeder, Scott B.
中科院分区:
文献类型:
--
作者:
Kijowski, Richard;Woods, Michael A.;Lee, Kenneth S.;Takimi, Kuya;Yu, Huanzhou;Shimakawa, Ann;Brittain, Jean H.;Reeder, Scott B.
To evaluate and quantify improvements in the quality of fat suppression for fast spin-echo imaging of the knee using multipeak fat spectral modeling and IDEAL fat-water separation. T1-weighted and T2-weighted fast spin-echo sequences with IDEAL fat-water separation and two frequency-selective fat-saturation methods (fat-selective saturation and fat-selective partial inversion) were performed on 10 knees of five asymptomatic volunteers. The IDEAL images were reconstructed using a conventional single-peak method and precalibrated and self-calibrated multipeak methods that more accurately model the NMR spectrum of fat. The signal-to-noise ratio (SNR) was measured in various tissues for all sequences. Student t-tests were used to compare SNR values. Precalibrated and self-calibrated multipeak IDEAL had significantly greater suppression of signal (P < 0.05) within subcutaneous fat and bone marrow than fat-selective saturation, fat-selective partial inversion, and single-peak IDEAL for both T1-weighted and T2-weighted fast spin-echo sequences. For T1-weighted fast spin-echo sequences, the improvement in the suppression of signal within subcutaneous fat and bone marrow for multipeak IDEAL ranged between 65% when compared to fat-selective partial inversion to 86% when compared to fat-selective-saturation. For T2-weighted fast spin-echo sequences, the improvement for multipeak IDEAL ranged between 21% when compared to fat-selective partial inversion to 81% when compared to fat-selective saturation. Multipeak IDEAL fat-water separation provides improved fat suppression for T1-weighted and T2-weighted fast spin-echo imaging of the knee when compared to single-peak IDEAL and two widely used frequency-selected fat-saturation methods.
登录
查看更多内容
影响因子:
3.3
作者:
MEYER, CH;PAULY, JM;NISHIMURA, DG
通讯作者:
NISHIMURA, DG
影响因子:
3.3
作者:
Pineda, AR;Reeder, SB;Pelc, NJ
通讯作者:
Pelc, NJ
影响因子:
19.7
作者:
Hauger, O;Dumont, E;Diard, F
通讯作者:
Diard, F
影响因子:
3.3
作者:
Reeder, SB;Pineda, AR;Pelc, NJ
通讯作者:
Pelc, NJ
影响因子:
5
作者:
Krinsky, G;Rofsky, NM;Weinreb, JC
通讯作者:
Weinreb, JC